How to choose the best DMM for your job?

Choosing the right digital multimeter (DMM) requires thinking about what you’ll be using it for. Evaluate your basic measurement needs and job requirements and then take a look at special features/functions built into many multimeters. Think about whether you need to do basic measurements, or if you need the more advanced troubleshooting options offered by special features.

Factors to consider:

• Your work environment (voltage level, types of equipment, types of measurements, applications)

• Specialty features/functions (capacitance, frequency, temperature, non-contact voltage, low impedance mode, min-max record, data logging, trending)

• Resolution and accuracy (6,000, 20,000, or 50,000 count resolution)

[/vc_column_text][bsf-info-box icon_size=”32″]

Safety:

The increased occurrence and levels of transient over voltages in today’s power systems have given rise to more stringent safety standards for electrical measurement equipment. Transients that ride on top of power sources (mains, feeder or branch circuits) can trigger a sequence of events that may lead to serious injury. Test equipment must be designed to protect people working in this high-voltage, high-current environment

[/bsf-info-box][/vc_column][/vc_row][vc_row][vc_column][vc_single_image image=”45056″ img_size=”large” alignment=”center”][vc_row_inner][vc_column_inner][vc_column_text]

 Category In Brief Examples
CAT 0 Electronic (Not directly connected to mains)
  • Protected electronic equipment.
  • Equipment connected to (source) circuits in which measures are taken to limit transient overvoltages to
    an appropriately low level.
  • Any high-voltage, low-energy source derived from a high-winding resistance transformer, such as the high-voltage section of a copier.
CAT II Appliances, PCs, and TVs
  • Appliance, portable tools, and other household and similar loads.
  • Outlet and long branch circuits.
  • Outlets at more than 10 meters (30 feet) from CAT III source.
  • Outlets more than 20 meters (60 feet) from CAT IV source.
CAT III MC panels, etc.
  • Equipment in fxed installations, such as switchgear and polyphase motors.
  • Bus and feeder in industrial plants.
  • Feeders and short branch circuits, distribution panel devices.
  • Lighting systems in larger buildings.
  • Heavy appliance outlets with short connections to service entrance.
CAT IV Three-phase at utility connection, any outdoor conductors
  • Refers to the “origin of installation,” i.e., where lowvoltage connection is made to utility power.
  • Electricity meters, primary overcurrent protection equipment.
  • Outside and service entrance, service drop from pole to building, run between meter and panel.
  • Overhead line to detached building, underground line to well pump.

[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_btn title=”GO TO FLUKE MULTI-METER SELECTOR” color=”info” size=”lg” align=”center” i_icon_fontawesome=”fa fa-share-square-o” button_block=”true” add_icon=”true” link=”url:http%3A%2F%2Ftotal-automation.in%2Ffluke-multimeter-selector%2F|||”][/vc_column][/vc_row]