[vc_row][vc_column][vc_column_text]

Models Compact meters Specialty meters
117 116 115 114 113 28II 27II 28IIEx
Basic features
Counts 6000 6000 6000 6000 6000 20000 6000 20000
True-rms readings AC AC AC AC AC AC AC
Basic DC accuracy 0.5% 0.5% 0.5% 0.5% 0.5% 0.05% 0.1% 0.05%
Wide bandwidth 20kHz 30kHz 20kHz
Auto/manual ranging Yes / Yes Yes / Yes Yes / Yes Yes / Yes Yes / Yes Yes / Yes Yes / Yes Yes / Yes
Digits 3-1/2 3-1/2 3-1/2 3-1/2 3-1/2 3-1/2 3-1/2 4-1/2
ATEX II 2G Eex ia IICT4 safety rating Zone 1 and Zone 2 Yes
Measurements
Voltage AC/DC 600V 600V 600V 600V 600V 1000V 1000V 1000V
Current AC/DC 10 A 600 μA 10 A 10 A 10 A 10 A
Resistance 40 M Ω 40 M Ω 40 M Ω 40 M Ω 60 M Ω 50 M Ω 50 M Ω 50 M Ω
Frequency 100 kHz 100 kHz 100 kHz 200 kHz 200 kHz 200 kHz
Capacitance 10,000 µF 10,000 µF 10,000 µF 10,000 µF 10,000 µF 10,000 µF 10,000 µF
Temperature (+) 400 °C (+) 1090 °C (+) 1090 °C
dB
Conductance 60 nS 60 nS 60 nS
Duty cycle/pulse width Yes / – Yes / – Yes / –
Continuity/diode test Yes Yes Yes Yes Yes Yes Yes Yes
Motor Drive (ASD) Measurements Yes Yes
VoltAlert™, non-contact voltage detection Yes
VCHEK™ Yes
LoZ: low input impedance Yes Yes Yes Yes
Lo Ohms
Microamps Yes Yes Yes Yes
Display
Wireless capabilities
Dot matrix display
Dual display
Analog bargraph Yes Yes Yes Yes Yes Yes Yes Yes
Backlight Two level Two level Two level
Graphical trend display
Diagnostics and data
Min Max recording/with time stamp Yes / – Yes / – Yes / – Yes / – Yes / – Yes / – Yes / – Yes / –
Fast Min Max 250 µs 250 µs
Display Hold/Auto (Touch) Hold Yes / – Yes / – Yes / – Yes / – Yes / – Yes / Yes Yes / Yes Yes / Yes
Relative reference Yes Yes Yes
Stand alone logging
Trend Capture
Readings memories
USB interface
Other features
Automatic selection, AC/DC volts Yes Yes Yes Yes
Real time clock
Overmolded case, integrated holster
Removable holster Yes Yes Yes Yes Yes Yes Yes Yes
Closed case calibration Yes Yes Yes Yes Yes Yes Yes Yes
Separate battery/fuse access Yes / – Yes / – Yes / – Yes /- Yes/- Yes /Yes Yes /- Yes/-
Completely sealed/ watertight Yes Yes Yes
Automatic power off Yes Yes Yes Yes Yes Yes Yes Yes
Low battery indication Yes Yes Yes Yes Yes Yes Yes Yes
Operating temperature range -10 °C, +50 °C -10 °C, +50 °C -10 °C, +50 °C -10 °C, +50 °C -10 °C, +50 °C -40 °C, +55 °C -40 °C, +55 °C -15 °C, +55 °C
Warranty and electrical safety
Warranty (years) 3 3 3 3 3 Lifetime Lifetime 3
Input alert Yes Yes Yes
Dangerous voltage indication Yes Yes Yes Yes Yes Yes Yes Yes
IP Rating IP42 IP42 IP42 IP42 IP42 IP67 IP67 IP67
EN61010-1 CAT III 600 V 600 V 600 V 600 V 1000 V 1000 V 1000 V
EN61010-1 CAT IV 600 V 600 V 600 V 600 V